<LOGO>
FM Transmitter Measurement Report
Created: 2024-08-28 09-55-28
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 69 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 2.8 kHz -84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 64 kHz 19040 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,5 dBr 4,87 dBr 6,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 64 kHz MIN: 8 kHz % above 76 kHz: 0,0000 Acquired: 2024/08/28 9.54.24 Total samples: 19040 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000 6000
FM Scope MAX: 6,5 dBr MIN: 3,5 dBr AVE: 4,87 dBr % above 12,2 dBr: 0,0 Last value: 5,4 dBr (2024/08/28 9.54.24) 09.40 09.42 09.44 09.46 09.48 09.50 09.52 09.54 0 2 4 6 Pm [dBr]